KIDDE AS964I

KIDDE addressable optical siren. direct connection to the loop. analogue control panels with apollo xp95 protocol, includes loop isolator. apollo xp95 protocol, occupies one address on the loop and is powered by it. red colour. sound output: 100 db. 3 alarm tones. certifications: ce and cpr (en54 parts 3 and 17). self-test fault supervision. alarm synchronisation.
More info

Reference 50040201

KIDDE AD68-0500

KIDDE digital thermal sensor cable 68º. pvc coating. 500m, lhd alarmline ii. approved to cul/ul 521 by fm (class 3210), up to 3000m. detection along the entire length of the cable, optional extrusions for different environments, simple installation and maintenance-free, suitable for hazardous areas. complies with rohs
More info

Reference 50040033

KIDDE PA25/3L

KIDDE conventional kilsen action indicator for fire detectors with 3 leds, two-wire connection, direct to detector, wide viewing angle, lights on four sides, low consumption. flashing. supply of 2 to 10 vdc, high brightness. red abs plastic polycarbonate housing, dimensions 80x80x42mm
More info

Reference 50040153

KIDDE 9-10908

KIDDE straight direct union for aspirating systems aritech red, for 27 mm pipe, abs material, red colour. indoor, en54-20 certification, dimensions 32 ø x 40.5 mm
More info

Reference 50040235

KIDDE SC-006-004

KIDDE sealed rechargeable lead-acid battery 6v 4ah (for smartcell control panel), for use with the smartcell control panel, nominal voltage 6 v, nominal capacity 4 ah, dimensions 70 x 105.5 x 47 mm, weight 0.87 kg
More info

Reference 50040029

KIDDE 9-30441

KIDDE interface card for kidde addressable panel, simple addressing on the loop, flat cable connection: no wiring, direct connection on the detector main board, easy address configuration, avoids the need to wire inputs and outputs manually
More info

Reference 50040230

KIDDE KE-IO3122

KIDDE intelligent addressable module, with 2 inputs / 2 outputs with isolator, loop powered. 2 addressable and programmable inputs and outputs, fully supervised two-level inputs for pre-alarm and alarm monitoring using a single input, output relays with magnetic latching, freely programmable. local test functions, clear local indication of operating status
More info

Reference 50040133

KIDDE NC-DPM-B

KIDDE conventional optical-thermal multisensor fire detector (black) programmable, supports dirt compensation. chamber contamination check, self-diagnostic. local test activation with reed switch, led visibility in all directions (360° view), configurable polling led support. remote indicator output, 2 programmable smoke sensitivity levels. interior ceiling
More info

Reference 50040089

KIDDE NC-MC-IP-100-R

KIDDE intelligent conventional manual fire alarm call point, red for outdoor use. alarm signalling via indicator and led, improved appearance with high-resolution screen-printed functional marking. resettable and also usable with an optional breakable element. protective cover with hinges and anti-tamper feature. resistance 100 ohm. possibility of carrying out tests with a key. back box, wall mounting.
More info

Reference 50040176

KIDDE NC-PF4

KIDDE conventional fire control panel, 4 zones. 32 devices/zone. 4 supervised relay outputs, fire and fault relays volt-free. en54 standard, networkable up to 64 zones. no language kit required. 2 non-supervised outputs, parts easily removable for quick and simple installation, support for normal zones, head-extraction zones and intrinsically safe zones, supervised alarm notification and pci outputs
More info

Reference 50040049

KIDDE SC-23-0220-0001-99

KIDDE smartcell dual smoke/heat detector siren with combined flash (white vad), wireless. compact profile. 32 tones, individual addressing. bidirectional communication 868 mhz., fire indication led. anti-tamper locking mechanism. ceiling mount, 3 er14505m batteries. output level 93 db(a). colour white, dimensions 110 x 58 mm (ø x d). weight 0.2 kg. certification cpr en54-3/5/7/13/23/25
More info

Reference 50040092

KIDDE ASW2366

KIDDE siren with flash for wall mounting aritech, low-profile base. red with red lens, loop or external power supply. output 97 db. low consumption, up to 32 tones, adjustable volume and flash, for multi-stage evacuation (up to 3 tones), automatic siren/beacon synchronisation. certificates: ce and cpr (en54)
More info

Reference 50040213

KIDDE N-MC-FC

KIDDE flip cover for manual call point, transparent for visibility of the leds and other elements in the manual call point., protects against accidental alarm activation. two steps, easy to install or adapt to any activsense call point, suitable for use with a tamper-evident seal for additional activation security, makes testing and maintenance easier without needing to lift the cover or remove the seal
More info

Reference 50040059

KIDDE NC-MC-100-RKIT

KIDDE conventional intelligent surface-mount push button, 100 ω red aritech, specifically designed for the manual activation of fire alarms., alarm indication via alarm indicator and alarm led, improved aesthetics with high-resolution screen-printed functional marking, resettable and also usable with an optional frangible element, surface-mount back box included
More info

Reference 50040164

KIDDE GRP26-09

KIDDE illuminated activated extinguishing sign for use with fire extinguishing control panel, plastic enclosure. 90db buzzer. high led light output, 3 interchangeable inserts: fire alarm, evacuate the area and extinguishing in progress. supply voltage: 24vdc (from 20vdc to 30vdc), low current consumption. sound output level of 90dba, dimensions 305x115x40 mm
More info

Reference 50040195