Filters: Detection
Please note: Not all products are currently visible in this filter. We are working to update this as soon as possible. Click this notification for an overview.
Notifier SD-851E A
Notifier Conventional optical smoke detector. Recommended for slow-moving fires, with visible smoke particles. Incorporates compensation algorithms.
B401 base mounted [205054004]
More info
Thermocable F3052 (100m)
Thermocable F3052 ProReact EN analogue resettable linear heat detector sensor cable with PVC and stainless steel braided cable coating for industrial environement. This stainless steel brained cable coating offers an increased mechanical toughness and abrasion resistance to the sensor cable. Suitable for indoor/outdoor use with limited exposure to direct sunlight and not exposed to harsh chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22 and VdS approved. It has been approved to Class A1I, A2I and BI. Roll of 100 meters
More info
Thermocable F3051 (100m)
Thermocable F3051 ProReact EN analogue resettable linear heat detector sensor cable with nylon cable coating for indoor/outdoor environment. This UV resistant nylon cable coating withstands better to direct sunlight and certain chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 100 meters
More info
Morley VSN-CO
Morley Morley Detector for carbon monoxide (CO). [209653001]
More info
Thermocable F3052 (200m)
Thermocable F3052 ProReact EN analogue resettable linear heat detector sensor cable with PVC and stainless steel braided cable coating for industrial environement. This stainless steel brained cable coating offers an increased mechanical toughness and abrasion resistance to the sensor cable. Suitable for indoor/outdoor use with limited exposure to direct sunlight and not exposed to harsh chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22 and VdS approved. It has been approved to Class A1I, A2I and BI. Roll of 200 meters
More info
Alpha 3-way valve
Alpha large 3-way 25mm ball valve
More info
Ajax EN54 FireProtect (Heat/Smoke)-W
Ajax EN54 FireProtect (Heat/Smoke), white. Wireless point smoke detector, battery 2x CR123A
More info
KIDDE KE-DP3121B
KIDDE detector, analogue dual optical thermal, intelligent addressable excellence series, black with isolator, integrated loop short-circuit isolator. short-circuit isolation on remote output, discrimination of noise, steam and dust. supports static temperature and rate of rise, alarm, pre-alarm, isolation, fault indicators, 360° indicator visibility. new mechanical rotary addressing, event log. certified alarm levels
More info
Notifier NCO100
Notifier CO detector with electrochemical probe + socket. [209453004]
More info
KIDDE KE-DP3121B-SNV
KIDDE optical thermal detector, dual, addressable, intelligent excellence series with isolator, siren and vad flash, (visual alarm device) black, integrated loop short-circuit isolator, on remote output, noise, vapour and dust discrimination. static temperature and rate-of-rise support, alarm, isolation, fault indicators, rotary addressing. certified en54. 32 tones. 4 levels. 86 db(a)
More info
Thermocable PACC+EOLU
Thermocable ProReact EN Analogue Composite Control (PACC) Unit + ProReact EN Analogue End-of-line (EOL) Unit monitors one detection zone of Analogue LHD cable with a maximum cable zone length of 500 metres. The unit offers a fault and pre-alarm and alarm output and can be interfaced to a conventional or analogue addressable fire panel. Protection rate : IP65. EN54-22, VdS and UL approved resetable analogue linair heat detection (LHD). The technology has been approved with up to 500 metres per zone for Classes A1I, A2I and BI as part of the EN54-22:2015 certificate. Minimum zone length is 30 metres for Class BI alarm setting and the minimum zone length is increased to 50 metres for the Class A1I/A2I alarm setting
More info
Honeywell F-INF-25-RF
Honeywell F-INF-25-RF filter set for F-INF-25
More info
Thermocable F3050 (200m)
Thermocable F3050 ProReact EN analogue resettable linear heat detector sensor cable with PVC cable coating for indoor environment. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 200 meters
More info
KIDDE NC-DPM-B
KIDDE conventional optical-thermal multisensor fire detector (black) programmable, supports dirt compensation. chamber contamination check, self-diagnostic. local test activation with reed switch, led visibility in all directions (360° view), configurable polling led support. remote indicator output, 2 programmable smoke sensitivity levels. interior ceiling
More info
Ajax EN54 FireProtect (Smoke)-W
Ajax EN54 FireProtect (Smoke) Jeweller, white. Wireless point smoke detector, battery 2x CR123A
More info