Other detectors
Thermocable Leader Cable (500m)
Thermocable F2990 Leader Cable with low smoke zero halogen cable coating for indoor and outdoor use. The cable coating is UV stable and oil resistant. The F2990 Leader Cable is used as a lead cable to create an insensitive detection zone when the linear heat detection cable is away from the control unit. Usable in both analog linear heat detection and digital linear heat detection. The maximum applicable length in analog linear heat detection : 250m and in digital linear heat detection : 1000m. Roll of 500 meters
More info
Thermocable EOLU-UL
Thermocable EOLU-UL ProReact end-of-line unit (EOLU) to terminate up-to two zones of ProReact UL digital LHD cable in a secure, IP66 weatherproof enclosure. Supplied with two IP67 cable glands. UL certified
More info
Thermocable F3050 (200m)
Thermocable F3050 ProReact EN analogue resettable linear heat detector sensor cable with PVC cable coating for indoor environment. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 200 meters
More info
Thermocable F3051 (500m)
Thermocable F3051 ProReact EN analogue resettable linear heat detector sensor cable with nylon cable coating for indoor/outdoor environment. This UV resistant nylon cable coating withstands better to direct sunlight and certain chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 500 meters
More info
Thermocable EN68SS (100m)
Thermocable EN68SS ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant and is protected by a stainless steel braid for an increased mechanical strength. Alarm temperature : 68°C, maximum ambient temperature : 45°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 100 meters
More info
Thermocable C1283 (100 pcs)
Thermocable C1283 silicone sleeve, max. ambient temperature : 180°C (price per 100 pieces, packaging unit = 100 pieces)
More info
Thermocable A1900
Thermocable A1900 ProReact EN analogue sensor cable test kit provides users with a practical and safe method of verifying the operational performance of Thermocable’s ProReact EN analogue sensor cable post-installation. A functional test is straightforward to be undertaken and a test kit can be re-used where necessary. The ProReact EN analogue sensor cable test kit (A1900) contains: 1x A1904 (120V/240Vac to 50Vac power supply), 1x A1901 (ProMinder red cable for zone lengths between 50m to 125m), 1x A1902 (ProMinder blue cable for zone lengths between 100 to 350m), 1x A1903 (ProMinder brown cable for zone lengths between 175m to 500m), 1x A1905 (35x450mm length 10mm internal diameter pipe insulation) and 1x A1175-100 (110°C constant rated indoor/outdoor tie wrap - pack of 100)
More info
Thermocable A1179 (100 pcs)
Thermocable A1179 steel edge clip for poutrel attachment 14-20mm, silicone sleeve not included. Max. load: 90 kg (price per 100 pieces, packaging unit = 100 pieces)
More info
Thermocable EN78 (200m)
Thermocable EN78 ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant. Alarm temperature : 78°C, maximum ambient temperature : 45°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 200 meters
More info
Thermocable DSCU-EN
Thermocable DSCU-EN ProReact Digital Sensor Control Unit (DSCU) monitors up-to two zones of Digital LHD cable and has separate fault and alarm outputs for each zone, max. 1000m ProReact EN digital linear heat detection cable per zone. EN54-28:2016 and UL certified
More info
Thermocable Leader Cable (100m)
Thermocable F2990 Leader Cable with low smoke zero halogen cable coating for indoor and outdoor use. The cable coating is UV stable and oil resistant. The F2990 Leader Cable is used as a lead cable to create an insensitive detection zone when the linear heat detection cable is away from the control unit. Usable in both analog linear heat detection and digital linear heat detection. The maximum applicable length in analog linear heat detection : 250m and in digital linear heat detection : 1000m. Roll of 100 meters
More info
Thermocable EN78 (500m)
Thermocable EN78 ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant. Alarm temperature : 78°C, maximum ambient temperature : 45°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 500 meters
More info
Thermocable EN88SS (100m)
Thermocable EN88SS ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant and is protected by a stainless steel braid for an increased mechanical strength. Alarm temperature : 88°C, maximum ambient temperature : 65°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 100 meters
More info
Thermocable PACC+EOLU
Thermocable ProReact EN Analogue Composite Control (PACC) Unit + ProReact EN Analogue End-of-line (EOL) Unit monitors one detection zone of Analogue LHD cable with a maximum cable zone length of 500 metres. The unit offers a fault and pre-alarm and alarm output and can be interfaced to a conventional or analogue addressable fire panel. Protection rate : IP65. EN54-22, VdS and UL approved resetable analogue linair heat detection (LHD). The technology has been approved with up to 500 metres per zone for Classes A1I, A2I and BI as part of the EN54-22:2015 certificate. Minimum zone length is 30 metres for Class BI alarm setting and the minimum zone length is increased to 50 metres for the Class A1I/A2I alarm setting
More info
Thermocable EN88SS (500m)
Thermocable EN88SS ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant and is protected by a stainless steel braid for an increased mechanical strength. Alarm temperature : 88°C, maximum ambient temperature : 65°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 500 meters
More info