Other detectors

75 Results

Thermocable EN88SS (100m)

Thermocable EN88SS ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant and is protected by a stainless steel braid for an increased mechanical strength. Alarm temperature : 88°C, maximum ambient temperature : 65°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 100 meters
More info

Reference 50027280

Thermocable PACC+EOLU

Thermocable ProReact EN Analogue Composite Control (PACC) Unit + ProReact EN Analogue End-of-line (EOL) Unit monitors one detection zone of Analogue LHD cable with a maximum cable zone length of 500 metres. The unit offers a fault and pre-alarm and alarm output and can be interfaced to a conventional or analogue addressable fire panel. Protection rate : IP65. EN54-22, VdS and UL approved resetable analogue linair heat detection (LHD). The technology has been approved with up to 500 metres per zone for Classes A1I, A2I and BI as part of the EN54-22:2015 certificate. Minimum zone length is 30 metres for Class BI alarm setting and the minimum zone length is increased to 50 metres for the Class A1I/A2I alarm setting
More info

Reference 50027000

Thermocable EN88SS (500m)

Thermocable EN88SS ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant and is protected by a stainless steel braid for an increased mechanical strength. Alarm temperature : 88°C, maximum ambient temperature : 65°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 500 meters
More info

Reference 50027282

Thermocable F1069 / 185°C (500m)

Thermocable F1069 ProReact digital linear heat detection cable for indoor/outdoor environment. Nylon cable coating. Activation temperature : 185°C, maximum ambient temperature : 125°C. UL and FM certified linear heat detection cable. Roll of 500 meters
More info

Reference 50027291

Thermocable EN68 (500m)

Thermocable EN68 ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant. Alarm temperature : 68°C, maximum ambient temperature : 45°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 500 meters
More info

Reference 50027242

Thermocable F3052 (100m)

Thermocable F3052 ProReact EN analogue resettable linear heat detector sensor cable with PVC and stainless steel braided cable coating for industrial environement. This stainless steel brained cable coating offers an increased mechanical toughness and abrasion resistance to the sensor cable. Suitable for indoor/outdoor use with limited exposure to direct sunlight and not exposed to harsh chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22 and VdS approved. It has been approved to Class A1I, A2I and BI. Roll of 100 meters
More info

Reference 50027070

Thermocable Leader Cable (200m)

Thermocable F2990 Leader Cable with low smoke zero halogen cable coating for indoor and outdoor use. The cable coating is UV stable and oil resistant. The F2990 Leader Cable is used as a lead cable to create an insensitive detection zone when the linear heat detection cable is away from the control unit. Usable in both analog linear heat detection and digital linear heat detection. The maximum applicable length in analog linear heat detection : 250m and in digital linear heat detection : 1000m. Roll of 200 meters
More info

Reference 50027451

Thermocable IS barrier kit for DLHD

Thermocable intrinsically safe barrier kit for use with digital linear heat detection. Kit contains : 2x IS-barriers mounted on DIN rail, IP66 enclosure and 2x IP66 cable glands
More info

Reference 50027203

Thermocable F3051 (100m)

Thermocable F3051 ProReact EN analogue resettable linear heat detector sensor cable with nylon cable coating for indoor/outdoor environment. This UV resistant nylon cable coating withstands better to direct sunlight and certain chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 100 meters
More info

Reference 50027060

Thermocable F1069 / 185°C (100m)

Thermocable F1069 ProReact digital linear heat detection cable for indoor/outdoor environment. Nylon cable coating. Activation temperature : 185°C, maximum ambient temperature : 125°C. UL and FM certified linear heat detection cable. Roll of 100 meters
More info

Reference 50027290

Thermocable A1329 (100 pcs)

Thermocable A1329 surface "P"-clip in stainless steel, including silicone sleeve. Dimensions : 12mm x 22mm (packing unit = 100 units)
More info

Reference 50027408

Thermocable JB-DLHD

Thermocable JB ProReact polycarbonate junction box with terminals, supplied with two cable glands
More info

Reference 50027202

Thermocable A1344 (100 pcs)

Thermocable A1344 steel edge clip for poutrel attachment 2-3mm, silicone sleeve not included. Max. load: 72 kg (price per 100 pieces, packaging unit = 100 pieces)
More info

Reference 50027403

Thermocable EN68 (200m)

Thermocable EN68 ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant. Alarm temperature : 68°C, maximum ambient temperature : 45°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 200 meters
More info

Reference 50027241

Thermocable EN88 (100m)

Thermocable EN88 ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant. Alarm temperature : 88°C, maximum ambient temperature : 65°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 100 meters
More info

Reference 50027260