Conventional Central Panels

11 Results

KIDDE NC-PF8

KIDDE conventional fire control panel 8 zones. 32 devices/zone. 4 supervised relay outputs, fire and fault relays volt-free. en54 standard, networkable up to 64 zones. no language kit required., 2 unsupervised outputs, parts easily removable for quick and easy installation, support for normal zones, head extraction and intrinsically safe zones, supervised alarm notification and pci outputs
More info

Reference 50040050

KIDDE 1X-X3E-09

KIDDE conventional programmable detection/extinguishing control panel kidde/aritech 3 zones, 2 cross-detection zones and 1 free programmable zone for extinguisher release, 6 supervised inputs (push buttons...). supports 4s modules (standard and supervised), supervised 4s sirens, 4s alarm and fault relay, 20 devices/zone. auxiliary power supply. reset support. requires 2 batteries. rs-485 analogue communication - 2010-1-nb card
More info

Reference 50040045

KIDDE NC-PX3-LK-21

KIDDE language template kit - portuguese for conventional fire alarm panel and extinguishing - 3 zones, dimensions: 219 x 18 x 301 mm, compatible nc-px3, weight 261 g, die-cut vinyl, portuguese language
More info

Reference 50040112

KIDDE NC-PX3

KIDDE conventional 3-zone fire detection and extinguishing control panel,, (template not included, please request separately in the chosen language), compatibility with normal supervision and zone output supervision., 6 preconfigured relays and 8 supervised inputs, configurable fire routing, siren, extinguishing, reset and door monitoring, configurable hold mode type a or type b, configurable sirens for pulsed or continuous operation
More info

Reference 50040047

KIDDE NC-PF2

KIDDE conventional fire control panel, 2 zones. 32 devices/zone. 2 supervised relay outputs, fire and fault relays volt-free. en54 standard, networkable up to 64 zones. no language kit required. 2 unsupervised outputs, parts easily removable for quick and simple installation, support for normal zones, head extraction and intrinsic safety zones, supervised alarm notification and pci outputs
More info

Reference 50040043

KIDDE 2010-1-RB

KIDDE module with 4 non-supervised outputs for conventional control panels, 4 potential-free com-no-nc changeover relay outputs, panel installation with easy installation without cables, bus type, powered from the panel bus, "and" and "or" programming functionality, output delay adjustment per output
More info

Reference 50040125

KIDDE 2010-1-NB

KIDDE network card for conventional control panels series 2010-1, 32 nodes/loops or 64 zones kilsen, allows the creation of a network of analogue and conventional control panels, supports class a or b networks. up to 1200 m between nodes. rs485 network. plug-in connectors, up to 32 nodes / 32 loops / 64 zones. direct connection to the control panel. no additional wiring is required, each node being a conventional or analogue fire control panel or repeater
More info

Reference 50040229

KIDDE NC-PF4

KIDDE conventional fire control panel, 4 zones. 32 devices/zone. 4 supervised relay outputs, fire and fault relays volt-free. en54 standard, networkable up to 64 zones. no language kit required. 2 non-supervised outputs, parts easily removable for quick and simple installation, support for normal zones, head-extraction zones and intrinsically safe zones, supervised alarm notification and pci outputs
More info

Reference 50040049

KIDDE NC-PX3-LK-09

KIDDE language template kit - spanish for conventional fire panel and extinguishing - 3 zones, dimensions: 219 x 18 x 301 mm, compatible nc-px3, weight 261 g, die-cut vinyl, spanish language
More info

Reference 50040111

KIDDE 1X-X3-09

KIDDE conventional programmable detection/extinguishing control panel kidde/aritech 3 zones, 2 cross-detection zones and 1 free programmable zone for extinguisher release, 6 supervised inputs (push buttons...) + 2 supervised. supports 4s modules (standard and supervised), 4s supervised sirens, 4s alarm and fault relay (volt-free), 20 devices/zone. auxiliary power supply. reset support. requires 2 batteries.
More info

Reference 50040046

KIDDE GBX2000

KIDDE galvanic isolator for conventional systems, certified with the iu2055 monitor module, eex ia iic output. tolerance 1%. device installation permitted in zone 2, protected against reverse polarity, emc in accordance with namur ne 21 standard, sil2 certification in accordance with iec 61508 standard
More info

Reference 50040007