EX detectors

21 Results

Please note: Not all products are currently visible in this filter. We are working to update this as soon as possible. Click this notification for an overview.

Brand Stock Class A Stock Class B
Addsecure 100% 100%
Ajax 100% -
Ajax Certified 100% -
Alpha 97% 75%
AlphaCable Fire 100% 100%
Aritech 100% -
Axis Communications 100% 100%
Berica Cavi Cable - 100%
Bosch Fire 88% 90%
Bysecur 100% -
Dahua 100% 100%
Durán 0% -
Eaton - 100%
Flir - 100%
Fulleon 100% 100%
Gas Safe Europe 100% 100%
Hanwha - 100%
Hikvision 100% 100%
Honeywell Fire - 98%
IQsight 100% 100%
Inim 100% 100%
Inim Addressable Fire 100% 100%
Inim Certified 100% -
Kidde 82% -
Lixit Lighting 100% 95%
Mobotix - 100%
Morley - 96%
Neutronic 97% 92%
Notifier - 97%
Orisec 100% 100%
Pulsar 100% 100%
RISCO 100% -
RWA 100% 100%
SEWOSY 100% 100%
STI 100% 98%
Sensomag 100% -
Thermocable 100% 94%
X-Sense 100% 100%
acre 100% 100%
elbaC - Alpha - 100%

Inim INE704C-2-RL

Inim INE704C-2-RL hydrogen detector (catalytic sensor) EX housing with integrated relay interface with 3 potential-free outputs (alarm, pre-alarm, and fault) for connection to a fire alarm control panel or alarm panel. Pre-alarm at 15% LEL and alarm at 30% LEL. The sensor is located at the bottom of the detector. This allows for easy replacement of the sensor at the end of its functional life. The detector can be maintained/adjusted using the programmer (handheld or PC). The gas detector is equipped with a cable gland connection. A cable gland with specifications NPT 1 inch can be screwed onto this (cable gland is not included with the product). Inim INA55-109 stainless steel mounting bracket available as an option.
More info

Reference 50013277

Thermocable IS barrier kit for DLHD

Thermocable intrinsically safe barrier kit for use with digital linear heat detection. Kit contains : 2x IS-barriers mounted on DIN rail, IP66 enclosure and 2x IP66 cable glands
More info

Reference 50027203

Inim INE704P-2-42

Inim INE704P-2-42 hydrogen detector (Pellistor sensor) EX housing with integrated 4-20mA interface for connection to an I/O input of the SmartLine or Previdia Micro fire alarm panel. Pre-alarm at 15% LEL and alarm at 30% LEL. The sensor is located at the bottom of the detector. This allows for easy replacement of the sensor at the end of its functional life. The detector can be maintained/adjusted using the programmer (handheld or PC). The gas detector is equipped with a cable gland connection. A cable gland with specifications NPT 1 inch can be screwed onto this (cable gland is not included with the product). Inim INA55-109 stainless steel mounting bracket available as an option.
More info

Reference 50013288

Inim INE704C-2-42

Inim INE704C-2-42 hydrogen detector (catalytic sensor) EX housing with integrated 4-20mA interface for connection to an I/O input of the SmartLine or Previdia Micro fire alarm panel. Pre-alarm at 15% LEL and alarm at 30% LEL. The sensor is located at the bottom of the detector. This allows for easy replacement of the sensor at the end of its functional life. The detector can be maintained/adjusted using the programmer (handheld or PC). The gas detector is equipped with a cable gland connection. A cable gland with specifications NPT 1 inch can be screwed onto this (cable gland is not included with the product). Inim INA55-109 stainless steel mounting bracket available as an option.
More info

Reference 50013276

Inim IR3-109/1CZ

Inim, IR3 flame detector for detection of flame burning. Intrinsically safe version.
More info

Reference 50005785
EAN/UPC 8050329021714

Inim INE706C-2-42

Inim INE706-42 propane detector (catalytic sensor) EX housing with integrated 4-20mA interface for connection to an I/O input of the SmartLine fire panel. The detector can be maintained/adjusted using the programmer (handheld or PC). The gas detector is equipped with a cable gland connection. A cable gland with specifications NPT 1 inch can be screwed onto this (cable gland is not included with the product). Inim INA55-109 stainless steel mounting bracket available as an option
More info

Reference 50013289
EAN/UPC 8050329024920

Inim Apollo ORB-OP-52027

Inim, Apollo Orbis conventional Ex optical detector.
More info

Reference 50005320
EAN/UPC 8050612420743

Inim Apollo ORB-OH-53027

Inim, Apollo Orbis Ex conventional multi-sensor detector.
More info

Reference 50005321
EAN/UPC 8050612420736

Inim Apollo ORB-HT-51151

Inim, Apollo Orbis Ex conventional thermoforming maximum detector.
More info

Reference 50005322
EAN/UPC 8050612420712

Inim Apollo ORB-HT-51145

Inim, Apollo Orbis Ex conventional thermodifferential detector.
More info

Reference 50005323
EAN/UPC 8050612424215

Inim Apollo 55000-640

Inim, Apollo Ex addressable optical detector (XP95)
More info

Reference 50005311
EAN/UPC 8050612420705

Inim Apollo 55000-440

Inim, Apollo Ex addressable thermal detector (XP95)
More info

Reference 50005312
EAN/UPC 8050612420699

Bosch OOH740-A9-EX

Bosch OOH740-A9-EX Dual-optical detector, explosive area Dual-optical detector for potentially explosive areas.
More info

Reference 50021709
EAN/UPC 4260451081447

Inim INE700S-2-LE

Inim INE700S-2-LE methane detector (semiconductor) EX housing with integrated interface for direct connection to the loop of the analog fire alarm control panel (Inim protocol). The detector can be maintained/adjusted using the programmer (handheld or PC). The gas detector is equipped with a cable gland connection. A cable gland with specifications NPT 1 inch can be screwed onto this (cable gland is not included with the product). Inim INA55-109 stainless steel mounting bracket available as an option
More info

Reference 50013205

Inim INE700C-2-42

Inim INE700C-2-42 methane detector (catalytic sensor) EX housing with integrated 4-20mA interface for connection to an I/O input of the SmartLine or Previdia Micro fire alarm panel. Pre-alarm at 15% LEL and alarm at 30% LEL. The sensor is located at the bottom of the detector. This allows for easy replacement of the sensor at the end of its functional life. The detector can be maintained/adjusted using the programmer (handheld or PC). The gas detector is equipped with a cable gland connection. A cable gland with specifications NPT 1 inch can be screwed onto this (cable gland is not included with the product). Inim INA55-109 stainless steel mounting bracket available as an option.
More info

Reference 50013271
EAN/UPC 8050329014990