Non-Resettable linear heat detection

31 Results

Please note: Not all products are currently visible in this filter. We are working to update this as soon as possible. Click this notification for an overview.

Brand Stock Class A Stock Class B
Addsecure 100% 100%
Ajax 100% -
Ajax Certified 100% -
Alpha 97% 75%
AlphaCable Fire 100% 100%
Aritech 100% -
Axis Communications 100% 100%
Berica Cavi Cable - 100%
Bosch Fire 88% 90%
Bysecur 100% -
Dahua 100% 100%
Durán 0% -
Eaton - 100%
Flir - 100%
Fulleon 100% 100%
Gas Safe Europe 100% 100%
Hanwha - 100%
Hikvision 100% 100%
Honeywell Fire - 98%
IQsight 100% 100%
Inim 100% 100%
Inim Addressable Fire 100% 100%
Inim Certified 100% -
Kidde 82% -
Lixit Lighting 100% 95%
Mobotix - 100%
Morley - 96%
Neutronic 97% 92%
Notifier - 97%
Orisec 100% 100%
Pulsar 100% 100%
RISCO 100% -
RWA 100% 100%
SEWOSY 100% 100%
STI 100% 98%
Sensomag 100% -
Thermocable 100% 94%
X-Sense 100% 100%
acre 100% 100%
elbaC - Alpha - 100%

Thermocable EOLU-EN

Thermocable EOLU-EN ProReact end-of-line unit (EOLU) to terminate up-to two zones of ProReact EN Digital LHD cable in a secure, IP66 weatherproof enclosure. Supplied with two IP67 cable glands. EN54-28:2016 and UL certified
More info

Reference 50027201

Thermocable IS barrier kit for DLHD

Thermocable intrinsically safe barrier kit for use with digital linear heat detection. Kit contains : 2x IS-barriers mounted on DIN rail, IP66 enclosure and 2x IP66 cable glands
More info

Reference 50027203

Thermocable EN88SS (500m)

Thermocable EN88SS ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant and is protected by a stainless steel braid for an increased mechanical strength. Alarm temperature : 88°C, maximum ambient temperature : 65°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 500 meters
More info

Reference 50027282

Thermocable EN125 (100m)

Thermocable EN125 ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant. Alarm temperature : 125°C, maximum ambient temperature : 85°C. EN54-28:2016 and UL certification in progress. Roll of 100 meters
More info

Reference 50027283

Thermocable JB-DLHD

Thermocable JB ProReact polycarbonate junction box with terminals, supplied with two cable glands
More info

Reference 50027202

Thermocable F1132 / 230°C (100m)

Thermocable F1132 ProReact digital linear heat detection cable for indoor/outdoor environment. Silicone rubber cable coating. Activation temperature : 230°C, maximum ambient temperature : 170°C. UL and FM certified linear heat detection cable. Roll of 100 meters
More info

Reference 50027297

Thermocable F1069 / 185°C (100m)

Thermocable F1069 ProReact digital linear heat detection cable for indoor/outdoor environment. Nylon cable coating. Activation temperature : 185°C, maximum ambient temperature : 125°C. UL and FM certified linear heat detection cable. Roll of 100 meters
More info

Reference 50027290

Thermocable EN68SS (500m)

Thermocable EN68SS ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant and is protected by a stainless steel braid for an increased mechanical strength. Alarm temperature : 68°C, maximum ambient temperature : 45°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 500 meters
More info

Reference 50027267

Thermocable EN78SS (500m)

Thermocable EN78SS ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant and is protected by a stainless steel braid for an increased mechanical strength. Alarm temperature : 78°C, maximum ambient temperature : 45°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 500 meters
More info

Reference 50027272

Thermocable EN88 (100m)

Thermocable EN88 ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant. Alarm temperature : 88°C, maximum ambient temperature : 65°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 100 meters
More info

Reference 50027260

Thermocable EN125 (200m)

Thermocable EN125 ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant. Alarm temperature : 125°C, maximum ambient temperature : 85°C. EN54-28:2016 and UL certification in progress. Roll of 200 meters
More info

Reference 50027284

Thermocable F1132 / 230°C (500m)

Thermocable F1132 ProReact digital linear heat detection cable for indoor/outdoor environment. Silicone rubber cable coating. Activation temperature : 230°C, maximum ambient temperature : 170°C. UL and FM certified linear heat detection cable. Roll of 500 meters
More info

Reference 50027298

Thermocable EN125 (500m)

Thermocable EN125 ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant. Alarm temperature : 125°C, maximum ambient temperature : 85°C. EN54-28:2016 and UL certification in progress. Roll of 500 meters
More info

Reference 50027285

Thermocable EN88 (200m)

Thermocable EN88 ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant. Alarm temperature : 88°C, maximum ambient temperature : 65°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 200 meters
More info

Reference 50027261

Thermocable F1127 / 110°C (500m)

Thermocable F1127 ProReact digital linear heat detection cable for indoor/outdoor environment. Low smoke zero halogen cable coating. Activation temperature : 110°C, maximum ambient temperature : 69°C. UL and FM certified linear heat detection cable. Roll of 500 meters
More info

Reference 50027296