Resettable linear heat detection
Please note: Not all products are currently visible in this filter. We are working to update this as soon as possible. Click this notification for an overview.
Thermocable F3052 (100m)
Thermocable F3052 ProReact EN analogue resettable linear heat detector sensor cable with PVC and stainless steel braided cable coating for industrial environement. This stainless steel brained cable coating offers an increased mechanical toughness and abrasion resistance to the sensor cable. Suitable for indoor/outdoor use with limited exposure to direct sunlight and not exposed to harsh chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22 and VdS approved. It has been approved to Class A1I, A2I and BI. Roll of 100 meters
More info
Thermocable F3051 (100m)
Thermocable F3051 ProReact EN analogue resettable linear heat detector sensor cable with nylon cable coating for indoor/outdoor environment. This UV resistant nylon cable coating withstands better to direct sunlight and certain chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 100 meters
More info
Thermocable F3052 (200m)
Thermocable F3052 ProReact EN analogue resettable linear heat detector sensor cable with PVC and stainless steel braided cable coating for industrial environement. This stainless steel brained cable coating offers an increased mechanical toughness and abrasion resistance to the sensor cable. Suitable for indoor/outdoor use with limited exposure to direct sunlight and not exposed to harsh chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22 and VdS approved. It has been approved to Class A1I, A2I and BI. Roll of 200 meters
More info
Thermocable PACC+EOLU
Thermocable ProReact EN Analogue Composite Control (PACC) Unit + ProReact EN Analogue End-of-line (EOL) Unit monitors one detection zone of Analogue LHD cable with a maximum cable zone length of 500 metres. The unit offers a fault and pre-alarm and alarm output and can be interfaced to a conventional or analogue addressable fire panel. Protection rate : IP65. EN54-22, VdS and UL approved resetable analogue linair heat detection (LHD). The technology has been approved with up to 500 metres per zone for Classes A1I, A2I and BI as part of the EN54-22:2015 certificate. Minimum zone length is 30 metres for Class BI alarm setting and the minimum zone length is increased to 50 metres for the Class A1I/A2I alarm setting
More info
Thermocable F3051 (200m)
Thermocable F3051 ProReact EN analogue resettable linear heat detector sensor cable with nylon cable coating for indoor/outdoor environment. This UV resistant nylon cable coating withstands better to direct sunlight and certain chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 200 meters
More info
Thermocable F3051 (500m)
Thermocable F3051 ProReact EN analogue resettable linear heat detector sensor cable with nylon cable coating for indoor/outdoor environment. This UV resistant nylon cable coating withstands better to direct sunlight and certain chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 500 meters
More info
Thermocable F3050 (500m)
Thermocable F3050 ProReact EN analogue resettable linear heat detector sensor cable with PVC cable coating for indoor environment. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 500 meters
More info
Thermocable F3050 (100m)
Thermocable F3050 ProReact EN analogue resettable linear heat detector sensor cable with PVC cable coating for indoor environment. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 100 meters
More info
Thermocable F3052 (500m)
Thermocable F3052 ProReact EN analogue resettable linear heat detector sensor cable with PVC and stainless steel braided cable coating for industrial environement. This stainless steel brained cable coating offers an increased mechanical toughness and abrasion resistance to the sensor cable. Suitable for indoor/outdoor use with limited exposure to direct sunlight and not exposed to harsh chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22 and VdS approved. It has been approved to Class A1I, A2I and BI. Roll of 500 meters
More info
Thermocable F3050 (200m)
Thermocable F3050 ProReact EN analogue resettable linear heat detector sensor cable with PVC cable coating for indoor environment. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 200 meters
More info
Thermocable JB-ALHD
Thermocable ProReact EN Analogue Junction Box is an optional component that can be employed to connect different lengths of ProReact EN analogue sensor cable together should it be required. Such instances could be if there is a desire to increase the total length of sensor cable within a zone. EN54-22 and VdS approved
More info
Bosch FCS-LHD-2EN
Bosch FCS-LHD-2EN Linear heat detector, VdS Conventional linear heat detector with LCD display.
More info
Bosch FCS-LHD2EN-EOL
Bosch FCS-LHD2EN-EOL End-of-line module, VdS Spare part, required for terminating sensor cable line.
More info
Bosch FCS-LHD2EN-CONN
Bosch FCS-LHD2EN-CONN Connection module, VdS Junction box to connect two sensor cables
More info
Bosch FCS-LHDSC-EN (100m)
Bosch FCS-LHDSC-EN Sensor cable PVC, VdS, red Sensor cable red, PVC outer sheath, resistant to dust and water. Price is per 100 m. delivery on reel.
More info