Other detectors

77 Results

Thermocable Leader Cable (500m)

Thermocable F2990 Leader Cable with low smoke zero halogen cable coating for indoor and outdoor use. The cable coating is UV stable and oil resistant. The F2990 Leader Cable is used as a lead cable to create an insensitive detection zone when the linear heat detection cable is away from the control unit. Usable in both analog linear heat detection and digital linear heat detection. The maximum applicable length in analog linear heat detection : 250m and in digital linear heat detection : 1000m. Roll of 500 meters
More info

Reference 50027452

Thermocable F3050 (200m)

Thermocable F3050 ProReact EN analogue resettable linear heat detector sensor cable with PVC cable coating for indoor environment. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 200 meters
More info

Reference 50027051

Thermocable F3051 (500m)

Thermocable F3051 ProReact EN analogue resettable linear heat detector sensor cable with nylon cable coating for indoor/outdoor environment. This UV resistant nylon cable coating withstands better to direct sunlight and certain chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 500 meters
More info

Reference 50027062

Thermocable C1283 (100 pcs)

Thermocable C1283 silicone sleeve, max. ambient temperature : 180°C (price per 100 pieces, packaging unit = 100 pieces)
More info

Reference 50027440

Thermocable PACC+EOLU

Thermocable ProReact EN Analogue Composite Control (PACC) Unit + ProReact EN Analogue End-of-line (EOL) Unit monitors one detection zone of Analogue LHD cable with a maximum cable zone length of 500 metres. The unit offers a fault and pre-alarm and alarm output and can be interfaced to a conventional or analogue addressable fire panel. Protection rate : IP65. EN54-22, VdS and UL approved resetable analogue linair heat detection (LHD). The technology has been approved with up to 500 metres per zone for Classes A1I, A2I and BI as part of the EN54-22:2015 certificate. Minimum zone length is 30 metres for Class BI alarm setting and the minimum zone length is increased to 50 metres for the Class A1I/A2I alarm setting
More info

Reference 50027000

Thermocable F3051 (200m)

Thermocable F3051 ProReact EN analogue resettable linear heat detector sensor cable with nylon cable coating for indoor/outdoor environment. This UV resistant nylon cable coating withstands better to direct sunlight and certain chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 200 meters
More info

Reference 50027061

Thermocable F3052 (100m)

Thermocable F3052 ProReact EN analogue resettable linear heat detector sensor cable with PVC and stainless steel braided cable coating for industrial environement. This stainless steel brained cable coating offers an increased mechanical toughness and abrasion resistance to the sensor cable. Suitable for indoor/outdoor use with limited exposure to direct sunlight and not exposed to harsh chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22 and VdS approved. It has been approved to Class A1I, A2I and BI. Roll of 100 meters
More info

Reference 50027070

Thermocable EN68SS (100m)

Thermocable EN68SS ProReact EN digital linear heat detection cable with low smoke zero halogen cable coating for indoor/outdoor environment. The cable coating is UV stable, oil resistant and flame retardant and is protected by a stainless steel braid for an increased mechanical strength. Alarm temperature : 68°C, maximum ambient temperature : 45°C. EN54-28:2016 and UL certified linear heat detection cable. Roll of 100 meters
More info

Reference 50027265

Thermocable F3051 (100m)

Thermocable F3051 ProReact EN analogue resettable linear heat detector sensor cable with nylon cable coating for indoor/outdoor environment. This UV resistant nylon cable coating withstands better to direct sunlight and certain chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 100 meters
More info

Reference 50027060

Thermocable F3052 (200m)

Thermocable F3052 ProReact EN analogue resettable linear heat detector sensor cable with PVC and stainless steel braided cable coating for industrial environement. This stainless steel brained cable coating offers an increased mechanical toughness and abrasion resistance to the sensor cable. Suitable for indoor/outdoor use with limited exposure to direct sunlight and not exposed to harsh chemicals. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22 and VdS approved. It has been approved to Class A1I, A2I and BI. Roll of 200 meters
More info

Reference 50027071

Thermocable EOLU-UL

Thermocable EOLU-UL ProReact end-of-line unit (EOLU) to terminate up-to two zones of ProReact UL digital LHD cable in a secure, IP66 weatherproof enclosure. Supplied with two IP67 cable glands. UL certified
More info

Reference 50027231

Notifier TMP2-JO-C-S-1-A

Notifier Eexd ATEX thermal detector of 90ºC, top entry, according to EN54/5 [205054016]
More info

Reference 50035013

Notifier TMP2-D-C-S-1-A

Notifier IP65 90ºC waterproof thermal detector according to EN54/5 [205054015]
More info

Reference 50035012

Thermocable F3050 (100m)

Thermocable F3050 ProReact EN analogue resettable linear heat detector sensor cable with PVC cable coating for indoor environment. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 100 meters
More info

Reference 50027050

Thermocable F3050 (500m)

Thermocable F3050 ProReact EN analogue resettable linear heat detector sensor cable with PVC cable coating for indoor environment. Thermocable’s ProReact EN Analogue LHD system compensates for ongoing changes in ambient temperature in order to reduce the likelihood of false alarms during operation putting it at an advantage over other linear heat detectors. Its rate-of-rise activation feature also allows for a response to quicker escalations in temperature around the sensor cable. Alarm temperature range : 54°C to 100°C. Maximum recoverable temperature : 125°C. The ProReact EN Analogue sensor cable does not have to be replaced following an alarm as long as the sensor cable is not subject to a temperature above its maximum recoverable temperature of 125⁰C. Minimum ambient temperature : -40°C. EN54-22, VdS and UL approved. It has been approved to Class A1I, A2I and BI. Roll of 500 meters
More info

Reference 50027052